Railway Cables
Railway Signalling & Control Cables Railway Telecom Cables Railway Power & Control Cables FIRERAIL Traction Cables

 

K25A Track Feeder Cables to NF F 55-625

 

Application

The cables are designed for fixed power or lighting installations in rail transport.

Standards

NF F 55-625

UNE 21123

Construction

K25A Track Feeder Cables to NF F 55-625

Conductors

Stranded bare copper conductor, 1.5mm² to IEC 60228 class 2.

Insulation

XLPE.

Filler & Inner Covering

LSZH.

Armour

Galvanized steel tapes.

Outer Sheath

LSZH, antitermite, coloured black.

Electrical Characteristics at 20℃

Nominal Conductor Cross Section mm² 1.5
Maximum DC Conductor Resistance Ω/km 12.2
Minimum Insulation resistance @500VDC MΩ.km 1500
Voltage Rating KV 0.6/1(0.45/0.75 optional)

Mechanical and Thermal Properties

Minimum Bending Radius: 10×OD

Temperature Range: -20℃ to +60℃ (during operation);

                                 -10℃ to +60℃ (during installation)

Core Identification

Colours coding: Black, Light blue, Brown, Green/Yellow, Black

Dimensions And Weight

Cable Code No. of cores& Nominal Conductor Cross
Sectional Area
No.×mm²
No. & Nominal Diameter of
Strands
No/mm
Minimum Overall
Diameter
mm
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
RF/K25A-RZ1F3Z1-U(AS)-0.6/1KV-2G1.5 2 x 1.5 7/0.53 8.0 12.0 100
RF/K25A-RZ1F3Z1-U(AS)-0.6/1KV-4G1.5 4 x 1.5 7/0.53 12.5 14.5 300
RF/K25A-RZ1F3Z1-U(AS)-0.6/1KV-12G1.5 12 x 1.5 7/0.53 18.0 20.0 590
RF/K25A-RZ1F3Z1-U(AS)-0.6/1KV-21G1.5 21 x 1.5 7/0.53 22.0 24.0 830